Hazard Zone Monitoring For Unplanned High-Risk Work

Three workers in helmets and high-visibility vests stand beside a barricaded hazard zone with caution tape around an open floor hatch in a factory.

Written by ARSA Writer Team

INDUSTRY GUIDE

A worker replacing a damaged skylight on a barn fell about ten metres through the roof, and on 3 November 2026 Warrington Magistrates' Court fined AJ Riley Landscapes and Building Limited and ordered £4,955 in costs. As HSE Blog reported, the Health and Safety Executive's investigation found inadequate planning and fall-prevention measures, along with too little training in the controls the company's own risk assessment specified. This guide shows how to put a camera-watched hazard zone around a short, one-off job like that one, so that someone is alerted when a person goes near the hazard. For one camera position, expect half a day from the permit to a tested alert.

OVERVIEW

What You Will Have Built

By the end you will have a marked hazard on site, a camera that can see the whole of it, a no-entry area drawn over that view, alerts that reach a named person, a walk test on record, and a close-out step that removes the zone once the job ends. The camera never replaces a guard rail, a cover or a crawling board. It tells you within seconds when someone has crossed a boundary that the physical controls were supposed to keep them behind.

Seven steps in order: write the hazard into the permit, choose the camera position, mount and connect, draw the area, route alerts, walk test, and close the zone.
Read As Text
  1. Write It Into The Permit Name the hazard and mark its boundary on a site photo.
  2. Choose The Position Find a camera spot that sees the whole zone at enough pixel density.
  3. Mount And Connect Fix the camera and pull its main stream with the clock synchronised.
  4. Draw The Area Trace the boundary as a no-entry area named after the permit.
  5. Route The Alerts Send alerts to the job supervisor and any siren at the area.
  6. Walk The Boundary Cross from every approach and confirm each crossing alerts.
  7. Close The Zone Switch it off and file the event log when the permit closes.

The law already treats the hazard as the thing to control. In the UK, regulation 9 of the Work at Height Regulations 2005 requires platforms, coverings or guard rails wherever someone has to work on or near a fragile surface, and warning notices at the approach. In the United States, OSHA 1926.501(b)(4) requires covers, guardrails or personal fall arrest where workers could fall through holes, skylights included, more than 6 feet. Monitoring adds a record of whether those controls held.

HAZARD TYPES

Three Kinds Of Temporary Hazard Zone

Non-routine work tends to create one of three hazards, each set up for a single job and easy to forget once that job is under way.

Fragile Roofs And Skylights

Roof lights, asbestos cement sheets and old profiled sheeting fail suddenly under a person's weight. The zone covers the fragile area plus the route people use to reach the work.

Open Excavations And Edges

A trench, an unprotected slab edge or a lift shaft opening shows up on Monday and is filled in by Friday. The zone follows the edge, and you redraw it as the edge moves.

Overhead Work And Suspended Loads

The area under a lift, a scaffold being struck or a crew working above. The zone is the drop footprint, which nobody should enter while the work runs.

PREPARATION

Before You Start

Get these together before anyone touches a camera:

  • The permit to work or method statement for the job, with the hazard named and its boundary marked on a drawing or photo
  • A competent person who decides how far the boundary sits from the hazard
  • An IP camera of 2 MP or better at 15 fps or more, streaming over RTSP or ONVIF, with time synchronised by NTP
  • A mounting point with a clear view of the entire zone, and an IP66 housing if the camera is outdoors
  • Network access from the camera to the analytics server or appliance, plus login rights to draw zones
  • The names of the people who receive alerts during the job, and a phone number for each
  • A second person for the walk test

Fitting a camera to a building edge, a pole or a roof is work at height in its own right. Plan it like any other job at height and have a qualified installer do it.

Step 1: Write The Hazard Into The Permit Before Anyone Starts

Put the exact hazard and its boundary into the permit to work before the job is approved. Have the competent person mark the boundary on a site photo, then add the zone name and the camera ID to the permit, so the monitoring is tied to that particular job. You have this step right when someone who has never seen the site can read the permit and point to the zone in the photo.

Step 2: Choose A Camera Position That Sees The Whole Zone

Choose a position where the camera can detect a person entering at the far edge of the zone. Under ARSA's published camera standard, ARSA-CVS-001, restricted-zone intrusion needs 71 pixels per metre (PPM) at the target. A 2 MP camera with a standard 60 degree lens reaches that density out to 23.6 m. Tilt the camera 15 to 40 degrees below horizontal, and keep it under 55. The zone needs at least 10 lux of light. The lens and field of view visualiser shows the wedge the camera will cover before you climb anything. A position works when the zone sits inside that wedge, nearer than the reach figure, and nothing such as a parapet, a stack of materials or the roof's own pitch blocks any part of it.

Table comparing zone entry at 71 PPM, 23.6 m reach, 55 degree maximum tilt and 10 lux with helmet checks at 262 PPM, 6.3 m, 35 degrees and 50 lux.
View The Data
RequirementZone EntryHelmet Check
Pixel density71 PPM262 PPM
Reach, 2 MP 60 degree lens23.6 m6.3 m
Max tilt55 degrees35 degrees
Minimum light10 lux50 lux
Requirement Restricted-Zone Intrusion Helmet Check, For Comparison
Pixel density at target 71 PPM 262 PPM
Reach on 2 MP, 60 degree lens 23.6 m 6.3 m
Tilt below horizontal Optimal 15 to 40 degrees, max 55 Optimal 10 to 25 degrees, max 35
Minimum light at target 10 lux 50 lux
Camera minimum 2 MP, 15 fps 2 MP, 15 fps

Source: ARSA-CVS-001 on the camera and site requirements page.

The table shows why a camera that is good enough for a zone may still be too far away to check helmets. Spotting entry into a zone needs far fewer pixels than PPE detection.

Step 3: Mount The Camera And Connect The Stream

Fix the camera firmly, aim it, and connect its stream to the analytics system. Pull the main stream from the camera directly where possible, turn smart codec modes and privacy masks off on that stream, and check the camera's clock against NTP. The connection is good when live video runs on the dashboard at the camera's full frame rate and the timestamp agrees with a phone clock to within a second.

Step 4: Draw The Hazard Area On The Camera View

Draw the hazard as a no-entry area on the camera's view, following the boundary marked in the permit photo. Trace the area where people would stand, set the area to no entry, and name it after the permit number. When a small crew is authorised to work inside, some systems can limit the area to authorised workers by face recognition. That needs each worker's consent and is normally off by default. You are done when the drawn area lines up with the physical barrier on the live view.

Step 5: Route Alerts To Someone Who Can Act

Send alerts to the supervisor responsible for the job, and to a siren or beacon at the work area if there is one. An alert reaches people a few seconds after someone enters. It cannot stop a machine or catch a person who is already falling, so it exists to get someone there quickly. Send a test alert and confirm every named person received it.

Step 6: Walk The Boundary And Record The Test

Have a second person walk up to the boundary from each direction of approach and step just inside it, while you watch for the alerts. Check that every crossing alerted, that each event's snapshot shows the person, and that the event time is right. If the job runs past dusk, repeat the test in the poorest light the shift will see. A pass means every approach alerted, and the test events go into the permit file.

Step 7: Close The Zone When The Permit Closes

When the permit is signed off, switch the zone off and export its event log. Attach the log to the permit file, then remove or reassign the camera. A zone left running after the hazard is gone sends false alarms that teach supervisors to ignore alerts, and that habit carries over to the next real one. This step is complete when the zone no longer appears as active and the log is in the permit file.

TROUBLESHOOTING

What Goes Wrong And How To Recognise It

The commonest failure is a camera set back too far. It shows the zone on screen, yet a person at the far edge covers too few pixels to detect, so the walk test alerts near the camera and misses at the back. If you see that pattern, move the camera closer or fit a narrower lens. Do not try to fix it in software. The second failure is occlusion that arrives after the test: a skip, a stack of sheeting or a parked telehandler blocks part of the view on the second day. Look at the live view at the start of each shift, as you would inspect a barrier.

Light causes the third problem. A zone that tested fine at midday can drop below 10 lux at dusk, and then detections start to miss without any error message. Run the walk test again whenever the hours of work change. The last failure is organisational. Alerts go to someone who is off site, or to a group inbox nobody reads during the job. Step 5 exists to prevent this, and it is worth repeating whenever the supervisor changes.

ARSA

Running This On ARSA Basic Safety Guard

ARSA's Basic Safety Guard detects a person entering a hazard area marked no entry. It runs on an AI Box at the site, or as software on servers you already own. Each event is logged with time, camera, zone and a snapshot, and the log exports as CSV, Excel or PDF for the permit file. Video is recorded on site and kept for 3 days by default, which you can set anywhere from 1 to 90 days. Zones are redrawn in the interface without retraining. ARSA delivers outside Indonesia. Where visa conditions keep ARSA engineers from travelling, a qualified local partner installs under ARSA supervision, and a Remote Camera Design Review checks camera positions against ARSA-CVS-001 before anything is installed. For more on site layouts, see the construction industry page.

FAQ

Hazard Zone Monitoring Questions

Can A Camera Replace Physical Fall Protection On A Fragile Roof?

No. Covers, guard rails, crawling boards and fall arrest remain the legal controls under both the UK Work at Height Regulations and OSHA. A camera adds a record and an alert when someone crosses the boundary those controls set.

How Far Away Can A Camera Detect Entry Into A Hazard Zone?

A 2 MP camera with a 60 degree lens detects zone entry out to 23.6 m. That distance is where it still delivers the 71 PPM that ARSA-CVS-001 requires. A narrower lens reaches roughly twice as far and covers a narrower area.

How Quickly Does An Alert Arrive?

Within a few seconds of entry. That is quick enough to send someone to the area or set off a siren, and too slow to stop a fall already happening, so prevention still depends on the physical controls.

Does Hazard Zone Monitoring Work At Night?

It does if the zone has at least 10 lux of light. Walk-test the zone in the darkest conditions the shift will face, because detection gets weaker as the light drops.

Can Authorised Workers Enter The Zone Without Raising An Alert?

They can where the system supports authorised-only areas, using face recognition of enrolled workers. That needs each worker's consent and is normally off. Without it, everyone who enters raises an alert, which suits a zone nobody should be in.

What Records Should Go Into The Permit File?

The walk test events, the full event log for the job, and the time the zone was closed. Each event should show the time, camera, zone and a snapshot, so the file shows whether the boundary held for the whole job.

For a reader who wants to see how this is done in practice, the PPE detection camera system shows hazard areas and PPE checks running on one appliance. To check your own site, send a few clips from your cameras for a free AI assessment by an ARSA engineer.

Read More Stories